TUV Certified IP67 Solenoid Locking Safety Door Switch

Product Details
Customization: Available
Structure: Extreme Limit Switch
Type: Explosion-Proof Limit Switch
Still deciding? Get samples of US$ 30/Piece
Request Sample
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 15 days
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (23)
  • TUV Certified IP67 Solenoid Locking Safety Door Switch
  • TUV Certified IP67 Solenoid Locking Safety Door Switch
  • TUV Certified IP67 Solenoid Locking Safety Door Switch
  • TUV Certified IP67 Solenoid Locking Safety Door Switch
  • TUV Certified IP67 Solenoid Locking Safety Door Switch
  • TUV Certified IP67 Solenoid Locking Safety Door Switch
Find Similar Products

Basic Info.

Model NO.
MA3-1BFG
Switching Element
Speed Switch
Application
Multi Contact Electromagnetic Locking Safety Door
Contactless Type
Inductive Switch
Contact
Contactless
OEM
Yes
Current Control
DC24V
Authentication
TUV
Ingress Protection
IP67
Security Protection
Force Lock
Material
PA66 Flame Retardant
Transport Package
Box
Specification
79*55*30MM
Trademark
zcmake
Origin
Shen Zhen
HS Code
8501400000
Production Capacity
50000/Pieces/Year

Product Description

Product Description
We take great pride in introducing our company as a leading manufacturer and sales supplier of a wide range of high-quality products. With our headquarters located in Guangdong, China, we have established ourselves as experts in the field of transmission belts, power supplies, switches, PCBs, and more. Our commitment to excellence and customer satisfaction sets us apart from the competition. We strive to deliver top-notch products that meet the highest industry standards. Our team of skilled professionals works diligently to ensure that every product leaving our factory is of superior quality and reliability. Trust us to provide you with the best transmission belts and other products that cater to your specific needs.
 
ELECTROMAGNETIC SAFETY-DOOR SWITCH
Multi contact electromagnetic locking safety door
switch
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
• IP67 degree of protection.
Variety of Metallic Heads Available..
Can be used for either standard loads or microloads.
Safety protection
Force lock
TUV EN 60947-5-1/IEC60947-5-1
GB/T 14048.5MA2 series operation manual
Model Number Structure
Model Number Legend
Switch (Standard type)
MA2- -
1 2 3 4 5
6 7
1. Conduit Outlet
1: Pg13.5
2: M20
2. Built-in Switch (with Door Open/Closed Detection
Switch and Lock Monitor Switch Contacts)
A: 1NC/1NO (slow-action contacts) + 1NC/1NO (slow-action contacts)
B: 1NC/1NO (slow-action contacts) + 2NC (slow-action contacts)
C: 2NC (slow-action contacts) + 1NC/1NO (slow-action contacts)
D: 2NC (slow-action contacts) + 2NC (slow-action contacts)
E: 2NC/1NO (slow-action contacts) + 1NC/1NO (slow-action contacts)
F: 2NC/1NO (slow-action contacts) + 2NC (slow-action contacts)
G: 2NC/1NO (slow-action contacts) + 2NC/1NO (slow-action contacts)
H: 3NC (slow-action contacts) + 1NC/1NO (slow-action contacts)
I : 3NC (slow-action contacts) + 2NC (slow-action contacts)
J: 3NC (slow-action contacts) + 3NC (slow-action contacts)
K: 3NC (slow-action contacts) +2NC/1NO (slow-action contacts)
L: 2NC/1NO (slow-action contacts) +3NC (slow-action contacts)
3. Head Mounting Direction and Material
F:Four mounting directions possible (Front-side mounting
at shipping)/plastic
D:Four mounting directions possible (Front-side mounting
at shipping)/metal
4. Door Lock and Release
A: Mechanical lock/24 VDC solenoid release
B: Mechanical lock/110 VAC solenoid release
G:24 VDC solenoid lock/mechanical release
H: 110 VAC solenoid lock/mechanical release
5. Release Key Position
F: Top
S: Front
6. Indicator
Blank: Standard DC24V (Green LED indicator)
B: orange LED indicator
7. Release Key Type
Blank: Standard (resin)
H: Specialrelease key (resin, Release tool is included.)
Note: it is not acceptable to order the switch head or switch
parts separately. (operating keys are sold separately.)
Operation Key
MAZ-D
1
Operation Key Type
1: Horizontal mounting
2: Vertical mounting
3: Adjustable mounting (horizontal)
4: Adjustable mounting (horizontal/vertical)MA2 series operation manual
List of Models
Switches (Operation Keys are sold separately.)
Consult with your NEWMAZZ representative when ordering any models that are not listed in this table.
Head
material
Solenoid voltage/
indicator
Lock and release
types
Contact configuration
(door open/closed
detection switch and lock
monitor switch contacts)
(slow-action)
Conduit outlet
Model
Plastic
Solenoid: 24 VDC
Green LED: 10 to 115
VAC/VDC
Mechanical lock
Solenoid release
1NC/1NO+1NC/1NO
Pg13.5
MA2-1AFAS
M20
MA2-2AFAS
1NC/1NO+2NC
Pg13.5
MA2-1BFAS
M20
MA2-2BFAS
2NC+1NC/1NO
Pg13.5
MA2-1CFAS
M20
MA2-2CFAS
2NC+2NC
Pg13.5
MA2-1DFAS
M20
MA2-2DFAS
2NC/1NO+1NC/1NO
Pg13.5
MA2-1EFAS
M20
MA2-2EFAS
2NC/1NO+2NC
Pg13.5
MA2-1FFAS
M20
MA2-2FFAS
2NC/1NO+2NC/1NO
Pg13.5
MA2-1GFAS
M20
MA2-2GFAS
3NC+1NC/1NO
Pg13.5
MA2-1HFAS
M20
MA2-2HFAS
3NC+2NC
Pg13.5
MA2-1IFAS
M20
MA2-2IFAS
3NC+3NC
Pg13.5
MA2-1JFAS
M20
MA2-2JFAS
3NC+2NC/1NO
Pg13.5
MA2-1KFAS
M20
MA2-2KFAS
2NC/1NO+3NC
Pg13.5
MA2-1LFAS
M20
MA2-2LFAS
Solenoid lock
Mechanical release
1NC/1NO+1NC/1NO
Pg13.5
MA2-1AFGS
M20
MA2-2AFGS
1NC/1NO+2NC
Pg13.5
MA2-1BFGS
M20
MA2-2BFGS
2NC+1NC/1NO
Pg13.5
MA2-1CFGS
M20
MA2-2CFGS
2NC+2NC
Pg13.5
MA2-1DFGS
M20
MA2-2DFGS
2NC/1NO+1NC/1NO
Pg13.5
MA2-1EFGS
M20
MA2-2EFGS
2NC/1NO+2NC
Pg13.5
MA2-1FFGS
M20
MA2-2FFGS
2NC/1NO+2NC/1NO
Pg13.5
MA2-1GFGS
M20
MA2-2GFGS
3NC+1NC/1NO
Pg13.5
MA2-1HFGS
M20
MA2-2HFGS
3NC+2NC
Pg13.5
MA2-1IFGS
M20
MA2-2IFGS
3NC+3NC
Pg13.5
MA2-1JFGS
M20
MA2-2JFGS
3NC+2NC/1NO
Pg13.5
MA2-1KFGS
M20
MA2-2KFGS
2NC/1NO+3NC
Pg13.5
MA2-1LFGS
M20
MA2-2LFGSMA2 series operation manual
Operation Keys
Dimensions and Operating(unit:mm)
Type
Model
Type
Model
Horizontal mounting
MAZ-D1
Adjustable mounting
(Horizontal)
MAZ-D3
Vertical mounting
MAZ-D2
Adjustable mounting
(Horizontal/
Vertical)
MAZ-D4
Type
Model
Safety door bolt
MAZ-K1MA2 series operation manual
Specifications
Electrical characteristics
Solenoid Coil Characteristics
LED indicator
Rated operating voltage
DC24V
Rated operating voltage
DC24V
power
4.8W
Rated current
Approx. 1 mA
Rated current
Approx. 200mA
Color (LED)
Green
insulation
Class F (155°C max.)
Safety level
Certification body
CCC(CQC),CE
Standards
EN60947-5-1,GB14048.5
Degree of protection
IP67 (EN60947-5-1)
Material Science
PA66 V0
Durability
Mechanical 1,000,000 operations min.
Electrical
6,000 operations min. (3A resistive load at 240 VAC)
Utilization category
AC-15
DC-13
Rated operating voltage(Ue)
240V
24V
Rated operating current(Ie)
3A
2A
Electrical
Contact resistance
25 mΩ max. (per contact)
Conventional free air thermal current (Ith)
10A
Rated insulation voltage (Ui)
300V
Protection against electric shock
Class II (double insulation)
Impulse withstand voltage (Uimp)(EN60947-5-1
)
2.5KV
Insulation resistance
100mMΩmin.
Short circuit protection device
10A,250V Quick break fuse is required
Vibration resistance
10 to 55 Hz,1.5mm single amplitude
Shock resistance
Destruction
1000m/s² min
Malfunction
300m/s² min
Insulation resistance
100A
Contact gap
2x2mm min.
Action characteristics
Direct opening force
60N min
Direct opening travel
10mm min
Operating speed
0.1m~0.5m/s
Operating frequency
30 operations/minute max.
Holding force (Fzh)
1300N
Ambient
Pollution degree(serviceenvironment)
3(EN60947-5-1)
Ambient operating temperature
-5ºC ~ + 40ºC
Ambient operating humidity
95% max.MA2 series operation manual
Model and Contact Configuration
Indicates conditions where theKey is inserted and the lock is applied. Terminals 12 and 41,22and51,32and61 are connected internally.
Model
Contact
(door open/closed
detection and lock
monitor))
Contact form
Operating pattern
Door open/
closed
detection
Lock
monitor
MA2-
AF
1NC/1NO+1NC/1NO
MA2-
BF
1NC/1NO+2NC
MA2-
CF
2NC+1NC/1NO
MA2-
DF
2NC+2NC
MA2-
EF
2NC/1NO+1NC/1NO
MA2-
FF
2NC/1NO+2NC
MA2-
GF
2NC/1NO+2NC/1NO
MA2-
HF
3NC+1NC/1NO
MA2-
IF
3NC+2NC
MA2-
JF
3NC+3NC
MA2-
KF
3NC+2NC/1NO
MA2-
LF
2NC/1NO+3NCMA2 series operation manual
Model
MA3
Key insertion force (Max)
15N
Key extraction force (Max)
50N
Pre-travel distance
9mm
Movement before being locked
3mmMA2 series operation manual
Operation Keys
MAZ-D1
MAZ-D3
MAZ-D2
MAZ-D4
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Safety door boltMA2 series operation manual
With Operation Key Inserted
Ensure that the alignment offset between the Operation Key and the key hole does not exceed ±1 mm. If
the Operation Key is offset or at an angle, accelerated wear or damage to the Switch may result.
• O bs e r v e th e spe c ifi ed in s e rtio n radi u s for th e O pe r a tion Ke y and
in s e rt it in a dir e c tion pe rpe ndi cu l a r to th e ke y ho l e
With Operation
Key Inserted
MA3+MAZ-D1
MA3+MAZ-D2
MA3+MAZ-D3
MA3+MAZ-D4
A Operation key
insertion position
44-46.5mm
40-42.5mm
45-47.5mm
51.9-54.4mm
B Operation key
insertion position
49.5-52mm
45.5-48mm
50.5-53mm
57.4-59.9mm
Horizontal
insertion radius: R
200mm
200mm
≥50mm
≥50mm
Vertical
insertion radius: R
200mm
200mm
200mm
≥50mm
Operation Key C
±1mm
±1mm
±1mm
±1mmMA2 series operation manual
Mounting
Installation
Do not use the Switch as a stopper.Be sure to install a stopper as shown in the following illustration to
ensure that the base of the Operation Key does not strike the
Head, and adjust the stopper to be within the setting zone (1 to 3mm) of the base of the Operation Key.
Do not subject the Switch to a shock that exceeds the Switch's shock resistance of 1,000 m/s 2 .
Securing the Door
When the door is closed (with the Operation Key inserted), the Operation Key may exceed the set zone
because of, for example, the door's own weight, machine vibration, or the door cushion rubber. Also, it may
not be possible to pull out the Operation Key if there is weight placed on the Operation Key. Secure the door
with a stopper so that the Switch is not included as the locking member of the door.
Set zone:MA2 series operation manual
Appropriate Tightening Torque
• When loosening a screw with an electrical screwdriver or similar tool while pressing down on the screw
head, do not continue turning the screw past the point where the threads disengage.Doing so may strip
the end of the threads.
Switch and Operation Key Mounting
• Use M4 screws and washers to mount the Switch and Operation Key, and tighten the screws to a suitable
torque.To ensure safety, use screws that cannot be easily removed or another means to prevent the Switch and
Operation Key from easily being removed.
• Do not impose excessive force on the Operation Key while the Key is inserted into the Switch or drop the
Switch with the Operation Key inserted. Doing either of these may deform the Key or break the Switch.
Terminal screw
0.6~0.8N·m
Cover mounting screw
0.5~0.7N·m
Head mounting screw
0.5~0.6N·m
Operation Key mounting screw
2.4~2.8N·m
Switch mounting screw
0.5~0.7N·m
Cable gland
1.8~2.2N·m
Cap screw
1.3~1.7N·mMA2 series operation manual
Wiring
• Do not wire the Switch while power is being supplied. Doing so may result in electric shock.
• Do not let particles, such as small pieces of lead wire, enter the switch body when wiring.
• When connecting to the terminals via insulating tube and M3.5 crimp terminals, cross the crimp terminals
as shown above so that they do not rise up onto the case or the cover.
• Applicable lead wire size: AWG20 to AWG18 (0.5 to 0.75 mm 2 ).Use lead wires of an appropriate length.
Not doing so may result in excess length causing the cover to rise and not fit properly.
• Do not push crimp terminals into gaps in the case interior. Doing so may cause damage or deformation of
the case.
• Use terminals having the thickness of 0.5 mm or less to avoid the contact between the terminal and the
interior of the Switch case.
Precautions for Safe Use
•DonotusetheSwitchsubmersedinoilorwaterorinlocationscontinuouslysubjecttosplashesofoilorwater.Doingsomayresult
inoilorwaterenteringtheSwitch.(TheIP67degreeofprotectionoftheSwitchspecifies theamountofwaterpenetrationafterthe
Switchissubmergedinwaterforacertainperiodoftime.)
•Donotswitchcircuits fortwoormorestandardloads(240VAC,3A).Doingsomayadverselyaffectinsulationperformance.
•Alwaysattachthecoverafter completingwiringandbeforeusingtheSwitch.Donotsupplypowerwhenthecoverisnotattached.
ElectricshockmayoccuriftheSwitchisusedwithoutthecover
attached.
Operation Key
• Use only the designated Operation Key. The Head has been designed so that operation is not possible
with a screwdriver or other tools. Using anything other than the designated Operation Key may damage the
Switch or affect machine safety.
• Do not operate the Switch with anything other than the special NEWMAZZ Operation Key, otherwise the
Switch may break or the safety of the system may not be maintained.
• Do not impose excessive force on the Operation Key while the Key is inserted into the Switch or drop the
Switch with the Operation Key inserted. Doing either of these may deform the Key or break the Switch..MA2 series operation manual
Head Direction
• Remove the four screws of the head to enable changing the mounting direction of the head. The head can be
mounted in four directions. Ensure that no foreign material enters the interior of the Switch.
• Do not change the head direction with the cover removed.
• Do not insert or remove the Operation Key with the Switch head removed. Doing so may make it impossible
to insert the Operation Key.
Solenoid
• The solenoid will heat when it carries current. Do not touch it.
• DC solenoid has polarity. Confirm terminal polarity before wiring it.
Release Key
• The release key is used to unlock the Switch in case of emergency or if the power supply to the Switch
stops.
• If the release key setting is changed from LOCK to UNLOCK, the lock will be released and the safety door
can be opened(mechanical lock models only).
• When a Switch with a solenoid lock is in a locked state (i.e., when the solenoid is ON), do not change the
release key from the LOCK to the UNLOCK position. Internal parts may be damaged.
• The release key is set in the unlock position at the factory for the MA2-FAS, Key insertion,You need to
energize the solenoid or rotate the unlocking knob to the unlocking position to pull out the key.
• Do not use the release key to start or stop machines.
• The auxiliary lock must only be released by authorized personnel.
• Do not impose a force exceeding 0.5 N·m on the release key screws.The release key may be damaged and
may not operate properly.
•To prevent the release key from being used by unauthorized personnel, set it to LOCK and seal it with
sealing wax.
Attaching a Cover
• When attaching a cover, be sure that the seal rubber is in place and that there is no foreign material present.
If the cover is attached with the seal rubber out of place or if foreign material is stuck to the rubber, a proper
seal will not be obtained.
• Do not use any screws to connect the cover other than the specified ones. The seal characteristics may be
reduced.
Solenoid lock
The door is locked only when the solenoid is turned ON. This means that the door will be unlocked if there
is a power interruption and so this model cannot be used in systems that would maintain a hazardous state
(e.g., systems requiring toxic gases,high temperatures, or gears that would continue to turn due to inertia).
Processing the Conduit Outlet
•Use a cable gland with the length of the screw not exceeding 9 mm to avoid interference with the inside of
the Switch case..
•Attach a conduit cap to the unused conduit outlet when wiring and tighten it to a suitable torque. The conduit
cap is provided with the Switch.MA2 series operation manual
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your NEWMAZZ representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. NEWMAZZ's exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by NEWMAZZ (or such other period expressed in writing by NEWMAZZ). NEWMAZZ
disclaims all other warranties, express or implied.
(b) Limitations. NEWMAZZ MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
NEWMAZZ further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. NEWMAZZ's sole obligation hereunder shall be, at
NEWMAZZ's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall NEWMAZZ be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless NEWMAZZ's analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by NEWMAZZ before shipment. NEWMAZZ Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
Limitation on Liability; Etc.
NEWMAZZ COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of NEWMAZZ Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
NEWMAZZ Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer's application or use of the Product. At Buyer's request, NEWMAZZ will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE NEWMAZZ PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Performance Data.
Data presented in NEWMAZZ Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of NEWMAZZ's test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the NEWMAZZ's Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your NEWMAZZ's representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by NEWMAZZ Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
TUV Certified IP67 Solenoid Locking Safety Door Switch
Multi contact electromagnetic locking safety door
switch
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
• IP67 degree of protection.
Variety of Metallic Heads Available..
Can be used for either standard loads or microloads.
Safety protection
Force lock
TUV EN 60947-5-1/IEC60947-5-1
GB/T 14048.5
 
TUV Certified IP67 Solenoid Locking Safety Door Switch
Multi contact electromagnetic locking safety door
switch
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
• IP67 degree of protection.
Variety of Metallic Heads Available..
Can be used for either standard loads or microloads.
Safety protection
Force lock
TUV EN 60947-5-1/IEC60947-5-1
GB/T 14048.5
 
TUV Certified IP67 Solenoid Locking Safety Door Switch
Model and Contact Configuration
Indicates conditions where theKey is inserted and the lock is applied. Terminals 12 and 41,22and51,32and61 are connected internally
 
TUV Certified IP67 Solenoid Locking Safety Door Switch
Ensure that the alignment offset between the Operation Key and the key hole does not exceed ±1 mm. If
the Operation Key is offset or at an angle, accelerated wear or damage to the Switch may result.
• O bs e r v e th e spe c ifi ed in s e rtio n radi u s for th e O pe r a tion Ke y and
in s e rt it in a dir e c tion pe rpe ndi cu l a r to th e ke y ho l e
 
TUV Certified IP67 Solenoid Locking Safety Door Switch
•DonotusetheSwitchsubmersedinoilorwaterorinlocationscontinuouslysubjecttosplashesofoilorwater.Doingsomayresult
inoilorwaterenteringtheSwitch.(TheIP67degreeofprotectionoftheSwitchspecifies theamountofwaterpenetrationafterthe
Switchissubmergedinwaterforacertainperiodoftime.)
•Donotswitchcircuits fortwoormorestandardloads(240VAC,3A).Doingsomayadverselyaffectinsulationperformance.
•Alwaysattachthecoverafter completingwiringandbeforeusingtheSwitch.Donotsupplypowerwhenthecoverisnotattached.
ElectricshockmayoccuriftheSwitchisusedwithoutthecover
attached.
Operation Key
• Use only the designated Operation Key. The Head has been designed so that operation is not possible
with a screwdriver or other tools. Using anything other than the designated Operation Key may damage the
Switch or affect machine safety.
• Do not operate the Switch with anything other than the special NEWMAZZ Operation Key, otherwise the
Switch may break or the safety of the system may not be maintained.
• Do not impose excessive force on the Operation Key while the Key is inserted into the Switch or drop the
Switch with the Operation Key inserted. Doing either of these may deform the Key or break the Switch..
Shenzhen Zhongchuang Automation Technology Co., Ltd. provides a variety of electrical products, and the current products provide a wide range of low-voltage electrical and automation control items, including MCB, MCCB, RCCB, contactors, inverters, solar systems, time relays, control relays, voltage relays, PLC relay modules, inverters, soft starters, timing switches, distribution boxes and other brand related accessories and components, which can meet your various needs. We adhere to the business principles of quality first, customer first and reputation-based; Since the establishment of the company, it has always done its best to meet the potential needs of its customers. Our company is sincerely willing to cooperate with enterprises all over the world to achieve a win-win situation.

The trend of economic globalization is developing unstoppably. Welcome to communicate and negotiate at any time. Sincerely care for customers, quality creates value, innovation and enterprising
FAQTUV Certified IP67 Solenoid Locking Safety Door SwitchTUV Certified IP67 Solenoid Locking Safety Door Switch
Q: How to arrange delivery?
A: If you have forwarder in China, we will delivey goods to them OR we arrange to delivery goods directly from factory by international express,by air and by sea di,it's up to you. 
 
Q: Can we get samples to test first before we buy it in bulk? 
A:Yes, we can arrage sampes if you need 
 
Q: Can we get support if we have our own market position? 
A:Yes, Please inform us your market demands,we will find suitable goods for you . 
 
Q: What  is payment terms?
A: T/T, L/C at sight, Western Union....

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier